




Subject: $2,749,000 · $1,248/sqft
$2,749,000
Designed by Architect Bing Thom, this is one of the city's most coveted concrete condominium buildings. Rarely available, this exquisite NW corner 2-level suite is w/in walking distance of the VanLawn and Tennis Club as well as the shops, dining & art along south Granville. With stunning views towards the mountains, water and downtown, the 2200 sq. ft. renovated suite exudes sophistication. It features beautiful renovated flooring, air con and sun-filled breakfast area. Large living on main floor with 2 bedrooms & 2 bath down, and additional 3rd bedroom and ensuite up to create ultimate privacy. Expansive living room takes advantage of all the north shore & Downtown views, or enjoy the quiet views of the Van Lawn & Tennis club. By Appointment
MLS #
R3022451
Status
Canceled
Type
Residential
Sub-type
Apartment/Condo
Ownership
Freehold Strata
Zoning
RM3
Bedrooms
3
Full Baths
3
Half Baths
0
Kitchens
1
Living Area
2,202 sqft
Main Floor
1,558 sqft
Above Main
644 sqft
Stories
13
Year Built
1993
Age
32 years
Roof
Torch-On
Construction
Concrete, Concrete (Exterior), Glass (Exterior), Mixed (Exterior)
Structure
Multi Family, Residential Attached
Parking Stalls
2
Parking Type
Garage Under Building, Lane Access
Original Price
$2,749,000
Strata Fee
$1,818.2/mo
Taxes
$8,821.43/yr
Listed
2025-07-03
MLS Area
Fairview VW
City
Vancouver
Postal Code
V6G 5J3
Subdivision
Bing Thom
Heating
Hot Water
Cooling / A/C
Central Air · Air Conditioning
Flooring
Laminate
Appliances
Washer/Dryer · Dishwasher · Refrigerator · Stove
Laundry
In Unit
Interior Features
Elevator
Exterior Features
Balcony
Total Units
19
Pets
Cats OK, Dogs OK, Number Limit (One), Yes With Restrictions
Restrictions
Pets Allowed w/Rest.,Rentals Allwd w/Restrctns
Strata Mgmt Co.
Dwell
Transit
close
Schools
close
View
North Shore Mountains, D/Town
Lot Features
Central Location, Recreation Nearby
Water Source
Public
Utilities
Electricity Connected, Natural Gas Connected, Water Connected
Community
Shopping Nearby
Building Amenities
Trash · Maintenance Grounds · Gas · Heat · Hot Water
Property Disclosure
Yes
Coordinates: 49.257739, -123.139944 · Map data © Google
Listed by Leung Realty & Associates Inc.
Source: City of Vancouver Open Data
Direct to Inspections - Addition / Alteration - Interior alterations to provide residential improvement to an existing dwelling unit at #701 - 1550 15th Ave. on the seventh and eight floor of this multiple dwelling building on the site. Okay for DTI per A. Best January 23, 2026 Schedule B to be determined on site by DBI
Multiple Dwelling
$500,000
Jan 29, 2026
BP-2026-00287
Direct to Inspections - Addition / Alteration - #202 Interior alterations to provide improvements to this dwelling unit (#202) on the second floor and to validate the work done installing a wall between bedrooms 1 and 2 of this existing multiple dwelling building on this site. OK for DTI per S. Shin April 16, 2025
Multiple Dwelling
$70,000
Apr 30, 2025
BP-2025-01847
Field Review - Addition / Alteration - #1200 Exterior and interior alterations to provide improvements to dwelling unit #1200 on the 12th floor of this existing multiple dwelling building on this site. Exterior work to remove a balcony enclosure. Scope of work includes demolition of non-loadbearing walls, new plumbing, electrical fixtures and millwork and interior finishes. OK for DB per B.Hudson OK for Field Review per L.Jayaraman Arch Sch A/B - Ryan Turner AIBC - 604-942-1215 Sch D - Julio Reynel-Gracia P.Eng - 778-998-0709 This building is sprinklered - separate sprinkler permit required for all related work If you are adding any HVAC equipment (including kitchen exhaust, and air make up air systems) that has an energy component such as motors (greater than 1 horse power) burners coils or heat exchangers you must submit Ashrae compliance Heat pumps must be rated no higher than 60 dB(A). It is the responsibility of the owner and the licensed contractor to ensure heat pumps are specified and sited to minimize the sound level transmission along property lines as required by the Noise Control Bylaw #6555.
Apartment
$400,000
Jun 13, 2024
DB-2024-01481
Field Review - Addition / Alteration - #401 Exterior and interior alterations to provide improvements to this dwelling unit #401 on the 4th floor of this multiple dwelling building on this site. Scope of work for the exterior includes the removal of the balcony enclosure and install windows, sliding doors, and guard rail with tempered glass. Interior work includes the removal of non-loadbearing partition wall in the kitchen and en-suite bathroom, renovation to kitchen, new floor finish, and new plumbing fixture in washroom and additional work related to electrical and plumbing. OK for Field Review per L.Williams, December 17, 2019 Notes: 1. Exterior colors to match existing. 2. CRP Schedule A & Architectural Schedule B submitted by Nicholas Waissbluth, 604.612.5095 3. Building Envelope Schedule D submitted by Julio Reynel-Garcia, P.Eng., 778.998.0709 4. Building inspector to determine on site if a separate sprinkler permit is required. 5. Energy Upgrade: L2 - HVAC - Install timers (up to 60 minute), or humidistat for laundry room fan\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t
Multiple Dwelling
$202,000
Feb 3, 2020
BP-2019-05708
High Density Housing / Commercial - Addition / Alteration - Elevator Upgrade - Interior alterations to provide elevator upgrades to one (1) elevator at the existing 13-storey multiple dwelling building on this site for CSA-B44-07 upgrade. Scope of work: - Replacement of existing heat detector at top of elevator shaft to smoke detector. - Upgrading existing circuits to addressable as required for elevator recall purposes. - Adding Q=6 new relays for additional recall control and automatic transfer signals for elevator operating on emergency power. Building Review Branch Notes: 1. Related Electrical Permit EP-2017-10238 2. Fire Safety Plan and or Operations Manual to be updated to show alterations. Plans to be submitted to Fire Prevention office for approval Evacuation plans for occupants to be updated. 3. Schedule B - Architectural & Electrical, S.J.F Jacob, P.Eng. Revision #1: Change elevator alternate recall level from 2nd floor to basement parkade, update elevator recall sequence of operations (2/E1.0), add elevator pit heat detector to riser diagram (2/E1.1) and parkade floor plan (1/E1.2), add egress paths to parkade (1/E1.2) and remove from 2nd floor level (1/E1.4), and update reference notes 2 & 3 (Page E1.3) regarding restricted access egress doors. P Volpi, Jan. 29, 2021
Multiple Dwelling
$16,600
Feb 21, 2018
BP-2017-06566